Auswahlhilfe MS- und NS-Verteilnetzarchitektur: Unterschied zwischen den Versionen
K (1 Version: Imported pages Chapter D (auto cleanup)) |
K (1 Version importiert: move to MW1.39) |
||
(6 dazwischenliegende Versionen von 3 Benutzern werden nicht angezeigt) | |||
Zeile 1: | Zeile 1: | ||
<!------------------------------------------------------------------------------------------------------------------------- | |||
---- define HERE the LETTER of this chapter (A...S). It is then used in different places further below, in this page | |||
-------------------------v------------------------------------------------------------------------------------------------- | |||
---->{{#vardefine:letter|D}}<!-- | |||
=== | --><div class="chapter-banner">[[File:Banner-chapter_{{#var:letter}}.jpg|class=chapter-banner-img|link=]]</div> | ||
{{Highlightbox|text= | |||
<!----------------------------------------------------------------------------------------------------------------------------- | |||
---- Description text for this chapter - START | |||
------------------------------------------------------------------------------------------------------------------------------> | |||
Bei der Planung mittlerer und großer Gebäude hat die Wahl der Energieverteilungsarchitektur einen entscheidenden Einfluss auf die Leistung der Anlage während ihres gesamten Lebenszyklus. | |||
In diesem Kapitel werden die wichtigsten zu berücksichtigenden elektrischen und umweltrelevanten Merkmale erläutert, einige Richtlinien und Empfehlungen zur Auswahl der Architektur sowie einige Bewertungskriterien zum Vergleich verschiedener Architekturen vorgeschlagen. Es wird auch erläutert, wie die Leistungsverluste mit der Barycenter-Methode minimiert werden können, wie in der Norm IEC 60364-8-1 "Elektrische Niederspannungsanlagen - Energieeffizienz" beschrieben. | |||
<!----------------------------------------------------------------------------------------------------------------------------- | |||
---- Description text for this chapter - END | |||
------------------------------------------------------------------------------------------------------------------------------> | |||
}} | |||
<!-- | |||
= | --><!----------------------------------------------------------------------------------- | ||
---add chapter TOC, based on Hierarchy (DO NOT MODIFY!) | |||
---------------------------------------------------------------------------------------- | |||
-->{{ch-toc|letter={{#var:letter}}}} | |||
<!-- ----------------------------------------------------------------------------------- | |||
---- define all properties and categories for this chapter landing page (DO NOT MODIFY!) | |||
---------------------------------------------------------------------------------------- | |||
-->__NOTOC__ __NOEDITSECTION__<!-- | |||
-->[[Has chapter letter::{{#var:letter}}| ]]<!-- | |||
-->{{#isin:{{MediaWiki:mainpage}}}}<!-- | |||
-->[[Category:eig-ch-landing-pages]]<!-- | |||
-->{{ch-category|{{#var:letter}}}}<!-- | |||
--><div>{{#addbodyclass:Chapter-TOC}}</div><!-- | |||
--><!-- -------------------------------------------------------------------------------> | |||
<!-- ---------------------------------------------------------------------------------------- | |||
---- ADD BELOW external links, inter-language links, and possibly other related content links | |||
--------------------------------------------------------------------------------------------> | |||
[[en:MV_and_LV_architecture_selection_guide]] | [[en:MV_and_LV_architecture_selection_guide]] |
Aktuelle Version vom 26. Januar 2024, 13:18 Uhr
Bei der Planung mittlerer und großer Gebäude hat die Wahl der Energieverteilungsarchitektur einen entscheidenden Einfluss auf die Leistung der Anlage während ihres gesamten Lebenszyklus.
In diesem Kapitel werden die wichtigsten zu berücksichtigenden elektrischen und umweltrelevanten Merkmale erläutert, einige Richtlinien und Empfehlungen zur Auswahl der Architektur sowie einige Bewertungskriterien zum Vergleich verschiedener Architekturen vorgeschlagen. Es wird auch erläutert, wie die Leistungsverluste mit der Barycenter-Methode minimiert werden können, wie in der Norm IEC 60364-8-1 "Elektrische Niederspannungsanlagen - Energieeffizienz" beschrieben.
Kapitel D - Inhaltsverzeichnis
- Nutzen für den Betreiber
- Vereinfachter Planungsansatz für die Verteilnetzarchitektur
- Leistungsmerkmale der elektrischen Anlage
- Technische Anforderungen
- Bewertungskriterien für die Verteilnetzarchitektur
- Auswahlmöglichkeiten der Verteilnetzarchitektur
- Detailplanung der Verteilnetzarchitektur
- Betriebsmittelauswahl
- Empfehlungen zur Optimierung der Verteilnetzarchitektur
- Begriffserklärung
- Beispiele: Elektroinstallation in einem Druckereibetrieb