Sandbox
table B8b
Nennspannungs-bereich der Sicherung (kV) des Transformators |
Absicherungsart ln Sicherung in A |
Trafo-Nennleistung in kVA | ||||||||||||||||||||||||||||||||||||
uK= 4 % | uK= 5 % | |||||||||||||||||||||||||||||||||||||
50 | 100 | 125 | 160 | 200 | 250 | 315 | 400 | 500 | 630 | 800 | 1000 | |||||||||||||||||||||||||||
[math]\displaystyle{ \frac {3,6/7,2}{6} }[/math] | Trafonennstrom | 4,8 | 9,6 | 12 | 15,4 | 19,2 | 24,1 | 30,3 | 38,5 | 48,1 | 60,6 | 77,1 | 96,3 | |||||||||||||||||||||||||
ohne | HH Sich. | 10 | 16 | 16 | 20 | 25 | 25 | 31,5 | 25 | 31,5 | 40 | 31,5 | 40 | 50 | 40 | 50 | 63 | 50 | 63 | 80 | 63 | 80 | 100 | 80 | 100 | 125 | 100 | 125 | 160 | 125 | 160 | 160 | ||||||
mit | HH-gL | 16 | 25 | 25 | 31,5 | 31,5 | 40 | 40 | 50 | 50 | 63 | 63 | 80 | 80 | 100 | 125 | 125 | 160 | 125 | 160 | - | |||||||||||||||||
mit | HH-gTr | 20 | 25 | 25 | 31,5 | 31,5 | 40 | 40 | 50 | 40 | 50 | 63 | 63 | 80 | 63 | 80 | 100 | 100 | 125 | 125 | 160 | 125 | 160 | 160 | ||||||||||||||
[math]\displaystyle{ \frac {7,2/12}{10} }[/math] | Trafonennstrom | 2,9 | 5,8 | 7,2 | 9,2 | 11,5 | 14,5 | 18,2 | 23,1 | 28,9 | 36,4 | 46,2 | 57,7 | |||||||||||||||||||||||||
ohne | HH Sich. | 10 | 16 | 20 | 16 | 20 | 20 | 25 | 25 | 31,5 | 25 | 31,5 | 40 | 31,5 | 40 | 50 | 40 | 50 | 63 | 50 | 63 | 80 | 63 | 80 | 100 | 80 | 100 | 100 | 125 | |||||||||
mit | HH-gL | 10 | 16 | 16 | 20 | 25 | 50 | 31,5 | 40 | 50 | 63 | 100 | (100) | (125) | ||||||||||||||||||||||||
mit | HH-gTr | 16 | 20 | 16 | 20 | 20 | 25 | 25 | 31,5 | 25 | 31,5 | 40 | 40 | 50 | 40 | 50 | 63 | 63 | 80 | 63 | 80 | 100 | 100 | 125 | ||||||||||||||
[math]\displaystyle{ \frac {12/17,5}{15} }[/math] | Trafonennstrom | 1,9 | 3,8 | 4,8 | 6,2 | 7,7 | 9,6 | 12,1 | 15,4 | 19,2 | 24,2 | 30,8 | 38,5 | |||||||||||||||||||||||||
ohne | HH Sich. | 6,3 | 10 | 16 | 16 | 20 | 16 | 20 | 20 | 25 | 25 | 31,5 | 31,5 | 40 | 31,5 | 40 | 50 | 40 | 50 | 63 | 63 | 80 | 100 | 63 | 80 | 100 | ||||||||||||
mit | HH-gL | (6,3) | 10 | 16 | 16 | 20 | 20 | 25 | 25 | 31,5 | 40 | 50 | 63 | 80 | 100 | - | ||||||||||||||||||||||
mit | HH-gTr | 10 | 10 | 16 | 16 | 20 | 16 | 25 | 20 | 25 | 25 | 31,5 | 31,5 | 40 | 40 | 50 | 50 | 63 | 63 | 80 | 100 | 80 | 100 | |||||||||||||||
[math]\displaystyle{ \frac {12/24}{20} }[/math] | Trafonennstrom | 1,5 | 2,9 | 3,6 | 4,6 | 5,8 | 7,2 | 9,1 | 11,5 | 14,4 | 18,2 | 23,1 | 28,9 | |||||||||||||||||||||||||
ohne | HH Sich. | 6,3 | 10 | 10 | 10 | 16 | 16 | 16 | 25 | 20 | 25 | 25 | 31,5 | 25 | 31,5 | 40 | 31,5 | 40 | 50 | 40 | 50 | 63 | 50 | 63 | 80 | |||||||||||||
mit | HH-gL | 6,3 | 10 | 10 | 16 | 16 | 25 | 25 | 25 | 31,5 | 40 | 50 | 63 | 80 | ||||||||||||||||||||||||
mit | HH-gTr | 10 | 10 | 10 | 16 | 16 | 16 | 20 | 25 | 25 | 25 | 31,5 | 31,5 | 40 | 40 | 50 | 50 | 63 | 63 | 80 | ||||||||||||||||||
[math]\displaystyle{ \frac {0,4/0,5}{0,4} }[/math] | Trafonennstrom | 72 | 144 | 180 | 231 | 289 | 361 | 465 | 577 | 722 | 909 | 1155 | 1443 | |||||||||||||||||||||||||
NH-gL | 80 | 125 | 160 | 200 | 250 | 315 | 400 | 500 | 630 | 800 | 1000 | 1250 | ||||||||||||||||||||||||||
NH-gTr | 72 | 144 | 180 | 231 | 289 | 361 | 455 | 577 | 722 | 909 | 1155 | 1443 |
references example
- [math]\displaystyle{ \mbox{Ia}=\frac{\mbox{Pn}}{\sqrt3\mbox{U}} }[/math] [1]
- [math]\displaystyle{ \mbox{Ia}=\frac{\mbox{Pn}}{\mbox{U}} }[/math] [1]
blablabla
blablabla
Notes
- ^ 1 2 Ia 单位:A;U 单位:V; Pn 单位:W。当 Pn 的单位是“kW”时,则该等式应乘以 1000。
- ^ 1 2 “功率因数校正”通常是指放光管术语中的“补偿”。cos φ 约为 0.95 (电压和电流的零位值几乎为同相),由于电流的脉冲形状。在每一半周期中,其波峰的形成产生了“滞后”,因而功率因数为 0.5。
Table example
table titles should be aligned to the left and top of cell ==> it will be OK with wiki3.2
Tube unit power requirement(W) |
Number of tubes corresponding to the power 16 A x 230 V |
Maximum number of tubes that can be controlled by | ||
---|---|---|---|---|
Contactors GC16 A CT16 A |
Remote control switches TL16 A |
'Circuit- breakers C60-16 'A | ||
18 | 204 | 15 | 50 | 112 |
36 | 102 | 15 | 25 | 56 |
58 | 63 | 10 | 16 | 34 |
Fig. N49: The number of controlled tubes is well below the number corresponding to the maximum power for the devices
NOTA: THIS IS A TEST OF MORE COMPLETE CLEAN-UP, TO BE CONFIRMED IF WE INCLUDE TABLE TITLE IN TABLE DIRECTLY
Tube unit power requirement(W) |
Number of tubes corresponding to the power 16 A x 230 V |
Maximum number of tubes that can be controlled by | ||
---|---|---|---|---|
Contactors GC16 A CT16 A |
Remote control switches TL16 A |
'Circuit- breakers C60-16 'A | ||
18 | 204 | 15 | 50 | 112 |
36 | 102 | 15 | 25 | 56 |
58 | 63 | 10 | 16 | 34 |
tables with other background colours in some lines-cells
Lamp power (W) | Number of lamps per circuit | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | |
MCB rating C tripping curve | ||||||||||||||||||||
Ferromagnetic ballast | ||||||||||||||||||||
35 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
70 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 16 | 16 | 16 |
150 | 6 | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 16 | 16 | 16 | 16 | 16 | 16 | 20 | 20 | 20 | 25 | 25 |
250 | 6 | 10 | 16 | 16 | 16 | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 32 | 32 | 32 | 32 | 40 | 40 |
400 | 6 | 16 | 20 | 25 | 25 | 32 | 32 | 32 | 32 | 32 | 32 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 63 | 63 |
1000 | 16 | 32 | 40 | 50 | 50 | 50 | 50 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 | 63 |
1800/2000 | 25 | 50 | 63 | 63 | 63 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Electronic ballast | ||||||||||||||||||||
35 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
70 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
150 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 20 | 20 | 20 |
MCB rating D tripping curve | ||||||||||||||||||||
Electronic ballast | ||||||||||||||||||||
35 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
70 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 16 | 16 | 16 |
150 | 6 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 16 | 16 | 16 | 16 | 16 | 16 | 20 | 20 | 20 | 25 | 25 |
250 | 6 | 6 | 10 | 10 | 16 | 16 | 16 | 16 | 16 | 20 | 20 | 25 | 25 | 25 | 32 | 32 | 32 | 32 | 40 | 40 |
400 | 6 | 10 | 16 | 16 | 20 | 20 | 25 | 25 | 25 | 32 | 32 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 63 | 63 |
1000 | 16 | 20 | 32 | 32 | 40 | 50 | 50 | 63 | 63 | - | - | - | - | - | - | - | - | - | - | - |
1800 | 16 | 32 | 40 | 50 | 63 | 63 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
2000 | 20 | 32 | 40 | 50 | 63 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Electronic ballast | ||||||||||||||||||||
35 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
70 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
150 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 20 | 20 | 20 |
Fig. N57: <Metal halide (with PF correction) - Vac = 230 V
Image example
Gallery example
This is to be used when several images have to be shown next to each other, with each a specific title (here: [a] ...) and a global figure title (it is quite rare, but happens)
It does not look nice now, but will be OK with the new look&feel
small manual TOC example
example with syntax to use (not looking perfect, will be ok with wiki3.2)
Inhaltsverzeichnis |
Highlight box ("green boxes" in the book) example
Standards and regulations distinguish two kinds of dangerous contact,
- Direct contact
- Indirect contact
and corresponding protective measures
math formula examples
- standard formula:
[math]\displaystyle{ Isc= \frac{420}{\sqrt 3 \sqrt {R_T\, ^2 + X_T\, ^2}} }[/math]
- formula inside Highlightbox
the grey colour does not seem right, but it will be OK with new wiki 3.2
This is an example with math formula inside Highlightbox [math]\displaystyle{ \definecolor{bggrey}{RGB}{234,234,234}\pagecolor{bggrey}Isc= \frac{420}{\sqrt 3 \sqrt {R_T\, ^2 + X_T\, ^2}} }[/math]
- formula inside table title:
the formula appears with the future blue background colour of table titles ==> it will be OK with new wiki 3.2
LV installation | R (mΩ) | X (mΩ) | RT (mΩ) | XT (mΩ) | [math]\displaystyle{ \definecolor{bggrey}{RGB}{65,193,232}\pagecolor{bggrey}Isc= \frac{420}{\sqrt 3 \sqrt {R_T\, ^2 + X_T\, ^2}} }[/math] | |
---|---|---|---|---|---|---|
LV | MV network Psc = 500 MVA |
0.035 | 0.351 |
Fig. G37: Example of short-circuit current calculations for a LV installation supplied at 400 V (nominal) from a 1,000 kVA MV/LV transformer
you can use this page to test wikitext language, it is free to modify by anybody
test6
[math]\displaystyle{ x^2 - y^2 +z^3 - a^{12} + \sqrt{\beta + 2.\pi.R + \delta + \phi} }[/math]
[math]\displaystyle{ {\rm THD}=\sqrt{\sum _{{\rm h}={\rm 2}}^{{\rm h}={\rm H}}\left(\frac{{\rm Y}_{{\rm h}} }{{\rm Y}_{{\rm 1}} } \right)^{{\rm 2}} } =\frac{\sqrt{{\rm Y}_{{\rm 2}}^{{\rm 2}} +{\rm Y}_{{\rm 3}}^{{\rm 2}} +...+{\rm Y}_{{\rm H}}^{{\rm 2}} } }{{\rm Y}_{{\rm 1}} } }[/math]
Color
Equations can use color:
{\color{Blue}x^2}+{\color{YellowOrange}2x}-{\color{OliveGreen}1}
- [math]\displaystyle{ {\color{Blue}x^2}+{\color{YellowOrange}2x}-{\color{OliveGreen}1} }[/math]
x_{1,2}=\frac{-b\pm\sqrt{\color{Red}b^2-4ac}}{2a}
- [math]\displaystyle{ x_{1,2}=\frac{-b\pm\sqrt{\color{Red}b^2-4ac}}{2a} }[/math]
It is also possible to change the background color (since r59550), as in the following example:
Background | Wikicode | Rendering (in PNG) |
---|---|---|
White | e^{i \pi} + 2 = 0
|
[math]\displaystyle{ e^{i \pi} + 2 = 0\,\! }[/math] |
\definecolor{orange}{RGB}{255,165,0}\pagecolor{orange}e^{i \pi} + 2 = 0
|
[math]\displaystyle{ \definecolor{orange}{RGB}{255,165,0}\pagecolor{orange}e^{i \pi} + 2 = 0\,\! }[/math] | |
Orange | e^{i \pi} + 2 = 0
|
[math]\displaystyle{ e^{i \pi} + 2 = 0\,\! }[/math] |
\definecolor{orange}{RGB}{255,165,0}\pagecolor{Green}e^{i \pi} + 2 = 0
|
[math]\displaystyle{ \definecolor{orange}{RGB}{255,165,0}\pagecolor{Green}e^{i \pi} + 2 = 0\,\! }[/math] |
[math]\displaystyle{ \color{Apricot}\text{Apricot} }[/math] | [math]\displaystyle{ \color{Aquamarine}\text{Aquamarine} }[/math] | [math]\displaystyle{ \color{Bittersweet}\text{Bittersweet} }[/math] | [math]\displaystyle{ \color{Black}\text{Black} }[/math] |
[math]\displaystyle{ \color{Blue}\text{Blue} }[/math] | [math]\displaystyle{ \color{BlueGreen}\text{BlueGreen} }[/math] | [math]\displaystyle{ \color{BlueViolet}\text{BlueViolet} }[/math] | [math]\displaystyle{ \color{BrickRed}\text{BrickRed} }[/math] |
[math]\displaystyle{ \color{Brown}\text{Brown} }[/math] | [math]\displaystyle{ \color{BurntOrange}\text{BurntOrange} }[/math] | [math]\displaystyle{ \color{CadetBlue}\text{CadetBlue} }[/math] | [math]\displaystyle{ \color{CarnationPink}\text{CarnationPink} }[/math] |
[math]\displaystyle{ \color{Cerulean}\text{Cerulean} }[/math] | [math]\displaystyle{ \color{CornflowerBlue}\text{CornflowerBlue} }[/math] | [math]\displaystyle{ \color{Cyan}\text{Cyan} }[/math] | [math]\displaystyle{ \color{Dandelion}\text{Dandelion} }[/math] |
[math]\displaystyle{ \color{DarkOrchid}\text{DarkOrchid} }[/math] | [math]\displaystyle{ \color{Emerald}\text{Emerald} }[/math] | [math]\displaystyle{ \color{ForestGreen}\text{ForestGreen} }[/math] | [math]\displaystyle{ \color{Fuchsia}\text{Fuchsia} }[/math] |
[math]\displaystyle{ \color{Goldenrod}\text{Goldenrod} }[/math] | [math]\displaystyle{ \color{Gray}\text{Gray} }[/math] | [math]\displaystyle{ \color{Green}\text{Green} }[/math] | [math]\displaystyle{ \color{GreenYellow}\text{GreenYellow} }[/math] |
[math]\displaystyle{ \color{JungleGreen}\text{JungleGreen} }[/math] | [math]\displaystyle{ \color{Lavender}\text{Lavender} }[/math] | [math]\displaystyle{ \color{LimeGreen}\text{LimeGreen} }[/math] | [math]\displaystyle{ \color{Magenta}\text{Magenta} }[/math] |
[math]\displaystyle{ \color{Mahogany}\text{Mahogany} }[/math] | [math]\displaystyle{ \color{Maroon}\text{Maroon} }[/math] | [math]\displaystyle{ \color{Melon}\text{Melon} }[/math] | [math]\displaystyle{ \color{MidnightBlue}\text{MidnightBlue} }[/math] |
[math]\displaystyle{ \color{Mulberry}\text{Mulberry} }[/math] | [math]\displaystyle{ \color{NavyBlue}\text{NavyBlue} }[/math] | [math]\displaystyle{ \color{OliveGreen}\text{OliveGreen} }[/math] | [math]\displaystyle{ \color{Orange}\text{Orange} }[/math] |
[math]\displaystyle{ \color{OrangeRed}\text{OrangeRed} }[/math] | [math]\displaystyle{ \color{Orchid}\text{Orchid} }[/math] | [math]\displaystyle{ \color{Peach}\text{Peach} }[/math] | [math]\displaystyle{ \color{Periwinkle}\text{Periwinkle} }[/math] |
[math]\displaystyle{ \color{PineGreen}\text{PineGreen} }[/math] | [math]\displaystyle{ \color{Plum}\text{Plum} }[/math] | [math]\displaystyle{ \color{ProcessBlue}\text{ProcessBlue} }[/math] | [math]\displaystyle{ \color{Purple}\text{Purple} }[/math] |
[math]\displaystyle{ \color{RawSienna}\text{RawSienna} }[/math] | [math]\displaystyle{ \color{Red}\text{Red} }[/math] | [math]\displaystyle{ \color{RedOrange}\text{RedOrange} }[/math] | [math]\displaystyle{ \color{RedViolet}\text{RedViolet} }[/math] |
[math]\displaystyle{ \color{Rhodamine}\text{Rhodamine} }[/math] | [math]\displaystyle{ \color{RoyalBlue}\text{RoyalBlue} }[/math] | [math]\displaystyle{ \color{RoyalPurple}\text{RoyalPurple} }[/math] | [math]\displaystyle{ \color{RubineRed}\text{RubineRed} }[/math] |
[math]\displaystyle{ \color{Salmon}\text{Salmon} }[/math] | [math]\displaystyle{ \color{SeaGreen}\text{SeaGreen} }[/math] | [math]\displaystyle{ \color{Sepia}\text{Sepia} }[/math] | [math]\displaystyle{ \color{SkyBlue}\text{SkyBlue} }[/math] |
[math]\displaystyle{ \color{SpringGreen}\text{SpringGreen} }[/math] | [math]\displaystyle{ \color{Tan}\text{Tan} }[/math] | [math]\displaystyle{ \color{TealBlue}\text{TealBlue} }[/math] | [math]\displaystyle{ \color{Thistle}\text{Thistle} }[/math] |
[math]\displaystyle{ \color{Turquoise}\text{Turquoise} }[/math] | [math]\displaystyle{ \color{Violet}\text{Violet} }[/math] | [math]\displaystyle{ \color{VioletRed}\text{VioletRed} }[/math] | [math]\displaystyle{ \pagecolor{Black}\color{White}\text{White} }[/math] |
[math]\displaystyle{ \color{WildStrawberry}\text{WildStrawberry} }[/math] | [math]\displaystyle{ \color{Yellow}\text{Yellow} }[/math] | [math]\displaystyle{ \color{YellowGreen}\text{YellowGreen} }[/math] | [math]\displaystyle{ \color{YellowOrange}\text{YellowOrange} }[/math] |
Note that color should not be used as the only way to identify something, because it will become meaningless on black-and-white media or for color-blind people. See Wikipedia:Manual of Style (accessibility).
[math]\displaystyle{ a^2-b^2=(a+b)*(a-b) }[/math]
[math]\displaystyle{ \sqrt(pi) }[/math]
list of standards for chapter A
IEC 60038 | VDE 0175 | IEC-Normspannungen |
IEC 60076-2 | VDE 0532-102 | Leistungstransformatoren - Übertemperaturen für flüssigkeitsgefüllte Transformatoren |
IEC 60076-3 | VDE 0532-3 | Leistungstransformatoren - Isolationspegel, Spannungsprüfungen und äußere Abstände in Luft |
IEC 60076-5 | VDE 0532-5 | Leistungstransformatoren - Kurzschlussfestigkeit |
IEC 60076-10 | VDE 0532-76-10 | Leistungstransformatoren - Bestimmung der Geräuschpegel |
IEC 60146-1-1 | VDE 0558-11 | Halbleiter-Stromrichter - Allgemeine Anforderungen und netzgeführte Stromrichter |
IEC 61810-1 | VDE 0435-201 | Elektromechanische Elementarrelais - Allgemeine Anforderungen |
IEC 62271-103 | VDE 0671-103 | Hochspannungs-Schaltgeräte und Schaltanlagen - Lastschalter für Bemessungsspannungen über 1 kV bis einschließlich 52 kV |
IEC 60269-1 | VDE 0636-1 | Niederspannungssicherungen - Allgemeine Anforderungen |
IEC 60269-2 | VDE 0636-2 | Niederspannungssicherungen - Zusätzliche Anforderungen an Sicherungen zum Gebrauch durch Elektrofachkräft bzw. elektrotechnisch unterwiesene Personen (Sicherungen überwiegend für den industriellen Gebrauch) |
IEC 60282-1 | VDE 0670-4 | Hochspannungssicherungen - Strombegrenzende Sicherungen |
IEC 60287-1-1 | Energiekabel - Berechnung des Bemessungsstroms - Gleichungen zur Berechnung des Bemessungsstroms (100 % Lastfaktor) und Berechnung von Energieverlusten - Allgemeines | |
IEC 60364 | VDE 0100 | Errichten von Niederspannungsanlagen |
IEC 60364-1 | VDE 0100-100 | Errichten von Niederspannungsanlagen - Allgemeine Grundsätze, Bestimmung allgemeiner Merkmale, Begriffe |
IEC 60364-4-41 | VDE 0100-410 | Errichten von Niederspannungsanlagen - Schutzmaßnahmen - Schutz gegen elektrischen Schlag |
IEC 60364-4-42 | VDE 0100-420 | Errichten von Starkstromanlagen bis 1000 V - Schutzmaßnahmen - Schutz gegen thermische Einflüsse |
IEC 60364-4-43 | VDE 0100-430 | Errichten von Niederspannungsanlagen - Schutzmaßnahmen - Schutz bei Überstrom |
IEC 60364-4-442 | VDE 0100-442 | Elektrische Anlagen von Gebäuden - Schutzmaßnahmen - Schutz bei Überspannungen - Schutz von Niederspannungsanlagen bei Erdschlüssen in Netzen mit höherer Spannung |
IEC 60364-4-443 | VDE 0100-443 | Errichtung von Niederspannungsanlagen - Schutzmaßnahmen - Schutz bei Störspannungen und elektromagnetischen Störgrößen - Schutz von Überspannungen infolge atmosphärischer Einflüsse oder von Schaltspannungen |
IEC 60364-4-444 | VDE 0100-444 | Errichtung von Niederspannungsanlagen - Schutzmaßnahmen - Schutz bei Störspannungen und elektromagn. Störgrößen |
IEC 60364-5-51 | VDE 0100-510 | Errichten von Niederspannungsanlagen - Auswahl und Einrichtung elektrischer Betriebsmittel - Allgemeine Bestimmungen |
IEC 60364-5-52 | VDE 0100-520 | Errichten von Niederspannungsanlagen - Auswahl und Einrichtung elektrischer Betriebsmittel - Kabel- und Leitungsanlagen |
IEC 60364-5-53 | VDE 0100-530 | Errichten von Niederspannungsanlagen - Auswahl und Einrichtung elektrischer Betriebsmittel - Schalt- und Steuergeräte |
IEC 60364-5-534 | VDE 0100-534 | Errichten von Niederspannungsanlagen - Auswahl und Errichtung elektrischer Betriebsmittel - Trennen, Schalten und Steuern - Überspannung-Schutzeinrichtungen (ÜSE) |
IEC 60364-5-534 | VDE 0100-537 | Elektrische Anlagen von Gebäuden - Auswahl und Errichtung elektrischer Betriebsmittel - Schaltgeräte und Steuergeräte - Geräte zum Trennen und Schalten |
IEC 60364-5-54 | VDE 0100-540 | Errichten von Niederspannungsanlagen - Auswahl u. Einrichtung elektrischer Betriebsmittel - Erdungsanlagen u. Schutzleiter |
IEC 60364-5-55 | VDE 0100-55-ff | Errichten von Niederspannungsanlagen - Auswahl und Einrichtung elektrischer Betriebsmittel - Andere Betriebsmittel |
IEC 60364-6 | VDE 0100-600 | Errichten von Niederspannungsanlagen - Prüfungen |
IEC 60364-7-701 | VDE 0100-701 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Räume mit Badewanne oder Dusche |
IEC 60364-7-702 | VDE 0100-702 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Becken von Schwimmbädern, begehbare Wasserbecken und Springbrunnen |
IEC 60364-7-703 | VDE 0100-703 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Räume und Kabinen mit Saunaheizungen |
IEC 60364-7-704 | VDE 0100-704 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Baustellen |
IEC 60364-7-705 | VDE 0100-705 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Elektrische Anlagen von landwirtschaftlichen und gartenbaulichen Betriebsstätten |
IEC 60364-7-706 | VDE 0100-706 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Leitfähige Bereiche mit begrenzter Bewegungsfreiheit |
IEC 60364-7-708 | VDE 0100-708 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Caravanplätze, Campingplätze und ähnliche Bereiche |
IEC 60364-7-709 | VDE 0100-709 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Marinas und ähnliche Bereiche |
IEC 60364-7-710 | VDE 0100-710 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Medizinisch genutzte Bereiche |
IEC 60364-7-711 | VDE 0100-711 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Ausstellungen, Shows und Stände |
IEC 60364-7-712 | VDE 0100-712 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Solar-Photovoltaik (PV) Stromversorgungssysteme |
IEC 60364-7-713 | VDE 0100-713 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Möbel |
IEC 60364-7-714 | VDE 0100-714 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Beleuchtungsanlagen im Freien |
IEC 60364-7-715 | VDE0100-715 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Kleinspannungsbeleuchtungsanlagen |
IEC 60364-7-717 | VDE 0100-717 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Ortsveränderliche oder transportable Baueinheiten |
IEC 60364-7-718 | VDE 0100-718 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Bauliche Anlagen für Menschenansammlungen |
IEC 60364-7-721 | VDE 0100-721 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Elektrische agen von Caravans und Motorcaravans |
IEC 60364-7-722 | VDE 0100-722 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Stromversorgungen Elektrofahrzeugen |
IEC 60364-7-723 | VDE 0100-723 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Unterrichtsräume Experimentiereinrichtungen |
IEC 60364-7-729 | VDE 0100-729 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Bedienungsgänge Wartungsgänge |
IEC 60364-7-740 | VDE 0100-740 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Vorübergehend ichtete Anlagen f. Aufbauten, Vergnügungseinrichtungen u. Buden auf Kirmesplätzen, in Vergnügungsparks u. Zirkussen |
IEC 60364-7-753 | VDE 0100-753 | Errichten von Niederspannungsanlagen - Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art - Fußbodenund ken-Flächenheizungen |
IEC 61439-1 | VDE 0660-600-1 | Niederspannungs-Schaltgerätekombinationen - Allgemeine Festlegungen |
IEC 61439-2 | VDE 0660-600-2 | Niederspannungs-Schaltgerätekombinationen - Energie Schaltgerätekombinationen |
IEC 61439-3 | VDE 0660-600-3 | Niederspannungs-Schaltgerätekombinationen - Installationsverteiler für die Bedienung durch Laien (DBO) |
IEC 61439-4 | VDE 0660-600-4 | Niederspannungs-Schaltgerätekombinationen - Besondere Anforderungen für Baustromverteiler (BV) |
IEC 61439-5 | VDE 0660-600-5 | Niederspannungs-Schaltgerätekombinationen - Schaltgerätekombinationen in öffentlichen Energieverteilungsnetzen |
IEC 61439-6 | VDE 0660-600-6 | Niederspannungs-Schaltgerätekombinationen - Schienenverteilersysteme (busways) |
IEC 61439-7 | VDE 0660-600-7 | Niederspannungs-Schaltgerätekombinationen - Schaltgerätekombinationen für Betriebsstätten . Räume und Anlagen besonderer , wie Marinas, Campingplätze, Marktplätze und ähnliche Anwendungen sowie Ladestationen für Elektrofahrzeuge |
IEC 60445 | VDE 0197 | Grund- und Sicherheitsregeln für die Mensch-Maschine-Schnittstelle - Kennzeichnung von Anschlüssen elektrischer Betriebsmittel, eschlossenen Leiterenden und Leitern |
IEC 60479-1 | VDE V | 0140-479-1 Wirkungen des elektrischen Stromes auf Menschen und Nutztiere - Allgemeine Aspekte |
IEC 60479-3 | VDE V | 0140-479-3 Wirkungen des elektrischen Stromes auf Menschen und Nutztiere - Wirkungen von Strömen durch den Körper von Nutztieren |
IEC 60479-4 | VDE V | 0140-479-4 Wirkungen des elektrischen Stromes auf Menschen und Nutztiere - Wirkungen von Blitzschlägen auf Menschen und Nutztiere |
IEC 60529 | VDE 0470-1 | Schutzarten durch Gehäuse (IP-Code) |
IEC 60644 | VDE 0670-401 | Anforderungen für Hochspannungs-Sicherungseinsätze für Motorstromkreise |
IEC 60664-3 | VDE 0110-3 | Isolationskoordination für elektrische Betriebsmittel in Niederspannungsanlagen - Anwendung von Beschichtungen, Eingießen r Vergießen zum Schutz gegen Verschmutzung |
IEC 60715 | Maße von Niederspannungsschaltgeräten - Genormte Tragschienen für die mechanische Befestigung von elektrischen Geräten Schaltanlagen. | |
IEC 60724 | Kurzschlusstemperaturgrenzwerte für Elektrokabel mit Bemessungsspannungen von 1 kV (Um = 1,2 kV) und 3 kV (Um = 3,6 kV) | |
IEC/TR | 60755 Allgemeine Anforderungen an Fehlerstromschutzeinrichtungen | |
IEC 60787 | VDE 0670-402 | Wechselstromschaltgeräte für Spannungen über 1 kV - Auswahl von strombegrenzenden Sicherungseinsätzen für Transformatorstromkreise |
IEC 60831-1 | VDE 0560-46 | Selbstheilende Leistungs-Parallelkondensatoren für Wechselstromanlagen mit einer Nennspannung bis 1 kV - Allgemeines - stungsanforderungen, Prüfung und Bemessung - Sicherheitsanforderungen - Anleitung für Errichtung und Betrieb |
IEC 60831-2 | VDE 0560-47 | Selbstheilende Leistungs-Parallelkondensatoren für Wechselstromanlagen mit einer Nennspannung bis 1 kV - Alterungsprüfung, bstheileprüfung und Zerstörungsprüfung |
IEC 60947-1 | VDE 0660-100 | Niederspannungsschaltgeräte - Allgemeine Festlegungen |
IEC 60947-2 | VDE 0660-101 | Niederspannungsschaltgeräte - Leistungsschalter |
IEC 60947-3 | VDE 0660-107 | Niederspannungsschaltgeräte - Lastschalter, Trennschalter, Lasttrennschalter und Schalter-Sicherungs-Einheiten |
IEC 60947-4-1 | VDE 0660-102 | Niederspannungsschaltgeräte - Schütze und Motorstarter - Elektromechanische Schütze und Motorstarter |
IEC 60947-5-5 | VDE 0660-201 | Niederspannungsschaltgeräte - Steuergeräte und Schaltelemente - Elektronisches NOT-AUS-Gerät mit mechanischer Verrastfunktion |
IEC 60947-6-1 | VDE 0660-114 | Niederspannungsschaltgeräte - Mehrfunktions-Schaltgeräte - Netzumschalter |
IEC 61000-2-ff | VDE 0839-2-ff | Elektromagnetische Verträglichkeit (EMV) - Umgebungsbedingungen |
IEC 61140 | VDE 0140-1 | Schutz gegen elektrischen Schlag - Gemeinsame Anforderungen für Anlagen und Betriebsmittel |
IEC 61557-1 | VDE 0413-1 | Elektrische Sicherheit in Niederspannungsnetzen bis AC 1000 V und DC 1500 V - Geräte zum Prüfen, Messen oder Überwachen Schutzmaßnahmen - Allgemeine Anforderungen |
IEC 61557-8 | VDE 0413-8 | Elektrische Sicherheit in Niederspannungsnetzen bis AC 1000 V und DC 1500 V - Geräte zum Prüfen, Messen oder Überwachen Schutzmaßnahmen - Isolationsüberwachungsgeräte für IT-Systeme |
IEC 61557-9 | VDE 0413-9 | Elektrische Sicherheit in Niederspannungsnetzen bis AC 1000 V und DC 1500 V - Einrichtungen zur Isolationsfehlersuche in IT-Systemen |
IEC 61558-2-6 | VDE 570-2-6 | Sicherheit von Transformatoren, Netzgeräten und dergleichen für Versorgungsspannungen bis 1100 V - Besondere Anforderungen Prüfungen an Sicherheitstransformatoren und Netzgeräte, die Sicherheitstransformatoren enthalten |
IEC 62271-1 | VDE 0671-1 | Hochspannungs-Schaltgeräte und -Schaltanlagen - Gemeinsame Bestimmungen |
IEC 62271-100 | VDE 0671-100 | Hochspannungs-Schaltgeräte und -Schaltanlagen - Wechselstrom-Leistungsschalter |
IEC 62271-101 | VDE 0671-101 | Hochspannungs-Schaltgeräte und -Schaltanlagen - Synthetische Prüfung |
IEC 62271-102 | VDE 0671-102 | Hochspannungs-Schaltgeräte und -Schaltanlagen - Wechselstrom-Trennschalter und -Erdungsschalter |
IEC 62271-103 | VDE 0671-103 | Hochspannungs-Schaltgeräte und -Schaltanlagen - Lastschalter für Bemessungsspannungen über 1kV bis einschließlich 52 kV |
IEC 62271-105 | VDE 0671-105 | Hochspannungs-Schaltgeräte und -Schaltanlagen - Hochspannungs-Lastschalter-Sicherungs-Kombinationen |
IEC 62271-200 | VDE 0671-200 | Hochspannungs-Schaltgeräte und -Schaltanlagen - Metallgekapselte Wechselstromschaltanlagen mit Bemessungsspannungen r 1 kV bis einschließlich 52 kV |
IEC 62271-201 | VDE 0671-201 | Hochspannungs-Schaltgeräte und -Schaltanlagen - Isolierstoffgekapselte Wechselstromschaltanlagen für Bemessungsspannungen r 1 kV bis einschließlich 52 kV |
IEC 62271-202 | VDE 0671-202 | Fabrikfertige Stationen für Hochspannung/Niederspannung |